• Welcome to MUST ENERGY !

Solar Inverters

Low Frequency Off Grid Solar Inverter

PV3500 TLV Series (AC:110/220V 8-12KW)

PV3500 TLV series is a multi-function inverter ,combining functions of inverter and MPPT solar charger controller, solar charger and battery chargerto offer uninterruptible power support. The comprehensive LCD display offers user-configurable and easy-accessible button operation such as batterycharging current, AC/solar charger priority, and selectable input voltage based on different applications.

Product Performance

  • Smart LCD setting(Working modes, Charge Current, Charge voltage, etc.)
  • Built-in MPPT solar charge controller 100A
  • MPPT efficiency max 98%
  • Powerful charge rate up to 80Amp
  • DC start &Automatic Self-Diagnostic Function
  • USB monitoring function
  • Supporting AGS, BTS port
  • Compatible to generator
MODEL PV35-8048 TLV PV35-10048 TLV PV35-12048 TLV
Nominal Battery System Voltage 48VDC
INVERTER OUTPUT
Rated power 8.0KW 10.0KW 12.0KW
Surge rating 24000VA 30000VA 36000VA
Capable of starting electric motor 4HP 5HP 6HP
Waveform Pure sine wave / same as input (bypass mode)
Nominal output voltage RMS 100V/110V/120V/200V/220V/240V
Output frequency 50Hz / 60Hz ± 0.3Hz
Inverter effciency(peak) >88%
Line mode efficiency >95%
Power factor 1.0
Typical transfer time 20ms(max)
AC INPUT
Voltage 220V/230V/240V
Selectable voltage range 90-280 VAC (APL)
Frequency range 50Hz / 60Hz
BATTERY
Low battery voltage cutoff 40-48VDC for 48VDC mode
Low battery voltage recover 42-50VDC for 48VDC mode
High battery voltage cutoff 60VDC for 48VDC mode
High battery voltage recover 57VDC for 48VDC mode
Idle consumption-search mode < 60W when power saver on
AC CHARGER
Output voltage Depends on battery type
Charger AC input breaker rating 80A 80A 80A
Overcharge protection S.D. 31.4VDC for 24VDC mode (62.8VDC for 48VDC mode )
Maximum charge current 60A 70A 80A
BTS
Continuous output power Yes Variances in charging voltage & S.D. voltage base on the battery temperature
BYPASS & PROTECTION
Input voltage waveform Sine wave (grid or generator)
Nominal input frequency 50Hz or 60Hz
Overload protection (SMPS Load) Circuit breaker
Output short circuit protection Circuit breaker
Bypass breaker rating 63A 63A 63A
Max bypass current 80Amp
SOLAR CHARGER
Maximum PV charge current 100A
DC voltage 48V
Maximim PV array power 5000W(10000W for 200A optional)
MPPT range @ operating voltage(VDC) 64~145VDC
Maximum PV array open circuit voltage 145VDC
Maximum effciency >98%
Standby power consumption <2W
MECHANICAL SPECIFICATIONS
Mounting Wall mount
Dimensions (W*H*D) 670*410*215mm
Net weight (solar CHG) (kg) 69+2.5 75.75+2.5 75.75+2.5
Shipping dimensions (W*H*D) 884*618*443mm
Shipping weight (Solar CHG) (kg) 82.5+2.5 89+2.5 92+2.5
OTHER
Operation temperature range 0°C to 40°C
Storage temperature -15°C to 60°C
Audible noise 60dB MAX
Display LED+LCD
Loading (20GP/40GP/40HQ) 140pcs / 280pcs / 320pcs