• Welcome to MUST ENERGY !

Data Center

Outdoor Micro Data Center

PTW Series (6-30KVA)

MUST Micro Modular Data Center developed with multiple configurations that fit into diverse application scenario. Fully integrated with outdoor type cabinet, UPS/DC power, battery, cooling, monitoring, security, and fire systems. Available with 2 cabinet and 3 cabinet all in one solution. The design platform with standardized modules and prefabricated size supports predicted deployment and quick customization.

MUST Data Center Benefits

It‘s a plug and play, totally enclosed and fully integrated solution built in with rack, power & battery, cooling, monitoring and security systems.

Easy Deployment

Pre-manufactured and fully tested means that no on-site engineering needed to activate the product. Within one day, you can deploy the IT equipments and quickly power on your business.

Easy Management

Design once and deploy anywhere. By this standardized architecture and remote monitoring access platform, you can gain control of these critical assets, reduce risks and operational costs, and improving service levels.

Easy Expansion

A stand alone full function solution. You can plan and invest your IT assets step by step while your business grows. Buy small and scale to big.Invest only when necessary.



MDC with Rack Cooling

  • MDC fully integrated with 2 rack space, rack cooling, AC/DC power, battery, power distribution, security, monitoring and fire systems.
  • IP55 protection and thermal insulated for outdoor deployment.

MDC with Inrow Cooling

  • MDC fully integrated with 2 rack space, rack cooling, AC/DC power, battery, power distribution, security, monitoring and fire systems.
  • IP55 protection and thermal insulated for outdoor deployment.
Model PTW-0616A PTW-0616B PTW-1018A Customized
Available Space -U 50 51 45 Per Definition
Redundancy N+1 N+1 N+1 N/N+1/2N
Width -mm 2000 2600 2600 2000/2600
Depth -mm 1600 1600 1600 1400/1600/1800
Height -mm 2300 2300 2300 2600 Max.
Weight -kg 600 900 920 Per Situation
Input Power Type 230V/ 1P/2P/ 50-60Hz 230V/ 1P/2P/ 50-60Hz 230V/ 1P/2P/ 50-60Hz Per Situation
Power Section
UPS -KVA 6 6 10 3/6/10/20/30
Mount Type Rack Rack Rack Rack
Standard Battery 12V/38AH 16Pcs 12V/38AH 20Pcs 12V/65AH 18Pcs 7-200Ah
PDU Basic 16Slots Basic 16Slots Basic 16Slots Basic/Smart
Cooling Section
Cooling Type Split DX Split DX Split DX Packaged/Split
Mount Type Rack Row Row Top/Rack/Row
Capacity-KW 3.9 5.6 7.6 40.9 Max.
Monitoring Section
Monitoring Function Touch Screen Touch Screen Touch Screen Touch Screen
Temp.&Hum. Temp.&Hum. Temp.&Hum. Temp.&Hum.
UPS Mgmt. UPS Mgmt. UPS Mgmt. UPS Mgmt.
Cooling Mgmt. Cooling Mgmt. Cooling Mgmt. Cooling Mgmt.
Smoke Sensor Smoke Sensor Smoke Sensor Smoke Sensor
Leaking Sensor Leaking Sensor Leaking Sensor Leaking Sensor
Door Status Door Status Door Status Door Status