Outdoor Micro Data Center

PTW Series (6-30KVA)

MUST Micro Modular Data Center developed with multiple configurations that fit into diverse application scenario. Fully integrated with outdoor type cabinet, UPS/DC power, battery, cooling, monitoring, security, and fire systems. Available with 2 cabinet and 3 cabinet all in one solution. The design platform with standardized modules and prefabricated size supports predicted deployment and quick customization.

MUST Data Center Benefits

It‘s a plug and play, totally enclosed and fully integrated solution built in with rack, power & battery, cooling, monitoring and security systems.

Easy Deployment

Pre-manufactured and fully tested means that no on-site engineering needed to activate the product. Within one day, you can deploy the IT equipments and quickly power on your business.

Easy Management

Design once and deploy anywhere. By this standardized architecture and remote monitoring access platform, you can gain control of these critical assets, reduce risks and operational costs, and improving service levels.

Easy Expansion

A stand alone full function solution. You can plan and invest your IT assets step by step while your business grows. Buy small and scale to big.Invest only when necessary.



MDC with Rack Cooling

  • MDC fully integrated with 2 rack space, rack cooling, AC/DC power, battery, power distribution, security, monitoring and fire systems.
  • IP55 protection and thermal insulated for outdoor deployment.

MDC with Inrow Cooling

  • MDC fully integrated with 2 rack space, rack cooling, AC/DC power, battery, power distribution, security, monitoring and fire systems.
  • IP55 protection and thermal insulated for outdoor deployment.
ModelPTW-0616APTW-0616BPTW-1018ACustomized
Available Space -U505145Per Definition
RedundancyN+1N+1N+1N/N+1/2N
Width -mm2000260026002000/2600
Depth -mm1600160016001400/1600/1800
Height -mm2300230023002600 Max.
Weight -kg600900920Per Situation
Input Power Type230V/ 1P/2P/ 50-60Hz230V/ 1P/2P/ 50-60Hz230V/ 1P/2P/ 50-60HzPer Situation
Power Section
UPS -KVA66103/6/10/20/30
Mount TypeRackRackRackRack
Standard Battery12V/38AH 16Pcs12V/38AH 20Pcs12V/65AH 18Pcs7-200Ah
PDUBasic 16SlotsBasic 16SlotsBasic 16SlotsBasic/Smart
Cooling Section
Cooling TypeSplit DXSplit DXSplit DXPackaged/Split
Mount TypeRackRowRowTop/Rack/Row
Capacity-KW3.95.67.640.9 Max.
Monitoring Section
Monitoring FunctionTouch ScreenTouch ScreenTouch ScreenTouch Screen
Temp.&Hum.Temp.&Hum.Temp.&Hum.Temp.&Hum.
UPS Mgmt.UPS Mgmt.UPS Mgmt.UPS Mgmt.
Cooling Mgmt.Cooling Mgmt.Cooling Mgmt.Cooling Mgmt.
Smoke SensorSmoke SensorSmoke SensorSmoke Sensor
Leaking SensorLeaking SensorLeaking SensorLeaking Sensor
Door StatusDoor StatusDoor StatusDoor Status