MPPT (Maximum Power Point Tracking)Solar Charge Controller offer an efficient, safe, multi-stage recharging process that prolongs battery life and assures peak performance from a solar array. Each Charge Controller allows customized battery recharging.
The default communication of the controller is RS485 port.You can use supplied cable to connect RS485,USB port of controller to PC.It can be used for monitoring or upgrade the firmware in short distance.
Equalization function reverses the buildup of negative chemical effects like stratification,a condition where acid concentration is greater at the bottom of the battery than at the top.Equalization also helps to remove sulfate crystals that might have built up on the plates.
PC1800A solar inverter system ,it can work with inverter , battery and solar panel , as a complete solar system and back up power for normal home power demands , which take use of sunshine free and save lots of electricity bill for you . This kind of solar inverter systems are widely used in home ,farm ,school,shops etc .
MODEL | PC18-6015F | PC18-8015F | PC18-10015F | |||
---|---|---|---|---|---|---|
Nominal Battery System Voltage | 12V/24V/48VDC (Auto detection); 36V (Setting) | |||||
CONTROLLER INPUT | ||||||
Battery Voltage | 12V | 24V | 36V | 48V | 48V | |
Maximum Solar Input Voltage | 100V | 145V | ||||
PV Array MPPT Voltage Range | 15~95V | 30~130V | 45~130V | 60~130V | 60~130V | |
Maximum Input Power | 12Volt-940W 24Volt-1880W 36Volt-2820W 48Volt-3760W | 12Volt-1250W 24Volt-2500W 36Volt-3750W 48Volt-5000W | 12Volt-1550W 24Volt-3100W 36Volt-4650W 48Volt-6200W | |||
BATTERY | ||||||
Charging Set Points | Absorption Stage | Float Stage | ||||
Flooded Battery | 14.2V/28.4V/42.6V/56.8V | 13.7V/27.4V/41.1V/54.8V | ||||
AGM (Default) | 14.4V/28.8V/43.2V/57.6V | 13.7V/27.4V/41.1V/54.8V | ||||
Over-charging Voltage | 15.5V/30.0V/45.0V/60.0V | |||||
Over-charging Comeback Voltage | 14.5V/29.5V/44.5V/59.0V | |||||
Battery Defect Voltage | 10.0V/17.0V/25.5V/34.0V | |||||
Temperature Compensation Conefficient | -5mv / ℃ /cell (25℃ vef) | |||||
Peak Conversion Efficiency | 98% (MPPT Efficiency 99%) | |||||
Max Charging Current | 60amps continuous @ 40℃ ambient | 80amps continuous @ 40℃ ambient | 100amps continuous @ 40℃ ambient | |||
GENERAL SPECIFICATION | ||||||
Radiating Mode | Fan cooling | |||||
DISPLAY & PROTECTION | ||||||
Protections | Solar high voltage disconnect Solar high voltage reconnect Battery high voltage disconnect Battery high voltage reconnect High temperature disconnect High temperature reconnect | |||||
MECHANICAL SPECIFICATIONS | ||||||
Mounting | Wall mount | |||||
Machine Dimension (W*H*D) | 152*85*294 mm (per pcs) | 175*82.9*257.1 | ||||
G.W (kg) | 3kg/pcs | |||||
Package Dimension (W*H*D) | 625*366*232 mm (4pcs / Carton) | / | ||||
Gross Weight (kg) | 14kg | |||||
OTHER | ||||||
Environmental Rating | Indoor | |||||
Operation Temperature Range | -10~55℃ | |||||
Ambient Humidity | 0~90% relative humidity (non-condensing) | |||||
Altiude | ≤3000m |