• Welcome to MUST ENERGY !

Power Wall Battery

Lithium Iron Phosphate Battery

LP16-51162 (51.2V/162Ah)

MUST LP1600 wall mounted Lithium battery is with a ground-breaking CATL & EVE LiFePO4 battery packsolutions are highly integrated, deep cycle backup power solutions for your solar home energy storage system. With rich experience and advanced techniques, the product has the features of the fashionable design, high energy, high power density, long service life, and easiness of installation.

APPLICATIONS

Lithium Iron Phosphate can be used in most applications that use Lead Acid, GEL or AGM type batteries.

Suitable applications include:

•Solar Storage
•Switching applications and more
•Base transceiver station
•Communication equipments
•Central office
•Telecommunication systems
•Electronic cash registers
•Microprocessor based office machine
•UPS

FEATURES & BENEFITS

High cycle life

4000 cycles @80% DoD for effectively lower total of ownership cost

Longer service life

Low maintenance batteries with stable chemistry.

Built in circuit protection

Battery Management System (BMS) is incorporated against abuse.

Better storage

up to 6 months thanks to its extremely low self discharge (LSD) rate and no risk of sulphation.

Quickly recharge

Save time and increase productivity with less down time thanks to superior charge/discharge efficiency.

Extreme heat tolerance

Suitable for use in a wider range of applications where ambient temperature is unusually high: up to +60°C.

Lightweight

Lithium batteries provide more Wh/Kg while also being up to 1/3 the weight of its SLA equivalent.

CAUTIONS

•Do NOT short circuit, reverse polarity, crush or disassemble.
•Do NOT heat or incinerate.
•Do NOT immerse in any liquid.
•Store at 30~50% SOC. Recharging every 3 months is recommended. The storage area should be clean, cool, dry and ventilated.

MODELLP16-51162
Nominal voltage51.2V
Nominal Capacity162Ah
Nominal energy8294.4Wh
Life Cycles4000+ (80% DoD for effectively lower total of ownership cost)
Recommended Charge Voltage58.4V
Recommended Charge Current0.2C(32.4A)
End of discharge voltage44.0V
Standard methodCharge32.4A
Discharge81A
Maximum continuous currentCharge162.0A
Discharge162.0A
BMS Cut-Off VoltageCharge<58.4V (3.65V/Cell)
Discharge>32.0V (2s) (2.0V/Cell)
TemperatureCharge-4 ~ 113 ℉ (0 ~ 45℃ )
Discharge-4 ~ 131 ℉ (-20 ~ 55℃ )
Storage Temperature23~95℃ (-5~35℃ )
Shipment voltage≥51.2V
CommunicationCAN2.0/RS232/RS485
Case MaterialSPPC
Charge retention and capacity recovery capabilityStandard charge the battery, and then put aside at room temperature for 28d or 55 ℃ for 7d, Charge retention rate≥90%, Recovery rate of charge≥90