• Welcome to MUST ENERGY !

Power Wall Battery

Lithium Iron Phosphate Battery

LP16-48100 (51.2V/100Ah)

MUST wall mounted Lithium battery (LiFePO₄ battery) solutions are highly integrated, deep cycle backup power solutions for your solar home energy storage system. With rich experience and advanced techniques, the product has the features of the fashionable design, high energy, high power density, long service life, and easiness of installation and expansion.

APPLICATIONS

Lithium Iron Phosphate can be used in most applications that use Lead Acid, GEL or AGM type batteries.

Suitable applications include:

•Solar Storage
•Switching applications and more
•Base transceiver station
•Communication equipments
•Central office
•Telecommunication systems
•Electronic cash registers
•Microprocessor based office machine
•UPS

FEATURES & BENEFITS

High cycle life

6000 Cycles (25℃, 80% DOD) for effectively lower total of ownership cost

Longer service life

Low maintenance batteries with stable chemistry.

Built in circuit protection

Battery Management System (BMS) is incorporated against abuse.

Better storage

up to 6 months thanks to its extremely low self discharge (LSD) rate and no risk of sulphation.

Quickly recharge

Save time and increase productivity with less down time thanks to superior charge/discharge efficiency.

Extreme heat tolerance

Suitable for use in a wider range of applications where ambient temperature is unusually high: up to +60°C.

Lightweight

Lithium batteries provide more Wh/Kg while also being up to 1/3 the weight of its SLA equivalent.

CAUTIONS

•Do NOT short circuit, reverse polarity, crush or disassemble.
•Do NOT heat or incinerate.
•Do NOT immerse in any liquid.
•Store at 30~50% SOC. Recharging every 3 months is recommended. The storage area should be clean, cool, dry and ventilated.

MODEL LP16-48100
Nominal voltage 51.2V
Nominal Capacity 100Ah
Nominal energy 5120Wh
Life Cycles 6000 Cycles (25℃, 80% DOD)
Recommended Charge Voltage 57.6V
Recommended Charge Current 20.0A
End of discharge voltage 44.0V
Standard method Charge 20.0A
Discharge 50.0A
Maximum  continuous current Charge 100.0A
Discharge 100.0A
BMS Cut-Off Voltage Charge <58.4 V (3.65V/Cell)
Discharge >32.0V (2s) (2.0V/Cell)
Temperature Charge -4 ~ 113 ℉ (0 ~ 45℃ )
Discharge -4 ~ 131 ℉ (-20 ~ 55 ℃ )
Storage Temperature 23~95 ℉ (-5~35℃ )
Shipment voltage ≥51.2V
Module Parallel Up to 4 units
Communication CAN2.0/RS232/RS485
Case Material SPPC
Dimension (L x W x H) 580 x 400 x 145mm
22.8 x 15.7 x 5.7”
Approx. Weight 97lbs (44kgs)
Charge retention and capacity recovery capability Standard charge the battery, and then put aside at room temperature for 28d or 55 ℃ for 7d, Charge retention rate≥90%, Recovery rate of charge≥90