The MUST HBP1800 Ⅱ Series is with a ground-breaking 1000Wh/2000Wh/3000Wh Lishen LiFePO4 battery pack and a 1000W/2000W/3000W rated pure sine wave AC inverter.Versatile energy storage system backs up in your home and scales, reliable access to power sources at any time. This class-leading power station brings you the power to run your entire party, family camping trip, cabin workshops, or even your whole house for a day or two in the event of an unexpected outage.
MODEL | HBP18 Ⅱ -1012 | HBP18 Ⅱ -2024 | HBP18 Ⅱ -3024 |
---|---|---|---|
AC model | |||
Inverter model | 1012 60A | 2024 60A | 3024 60A |
Rated power | 1000W | 2000W | 3000W |
AC input voltage | 230Vac ±5% | ||
Nominal input frequency | 50Hz / 60Hz (Auto detection) | ||
Transfer time | 10ms typical (UPS, VDE); 20ms typical (APL) | ||
Inverter model | |||
Output voltage wavefrom | Pure sine wave | ||
Output voltage regulation | 230Vac±5% | ||
Output frequency | 50Hz or 60Hz (±0.2Hz) | ||
Peak efficiency | 90% | ||
Nominal DC input voltage | 12Vdc (±0.3) | 24Vdc (±0.3) | 24Vdc (±0.3) |
Low DC warning voltage | 10.7VDC | 21.4VDC | 21.4VDC |
Low DC warning return voltage | 10.6VDC | 21.2VDC | 21.2VDC |
Low DC cut-off voltage | 10.2VDC | 20.4VDC | 20.4VDC |
High DC recovery voltage | 14.5V | 29Vdc | 29Vdc |
High DC cut-off voltage | 15.0V | 30Vdc | 30Vdc |
Standby Consumption | < 25W | < 25W | < 25W |
Utility charging model | |||
Charging current @ Nominal input voltage | 10/20A (±4A) | 10/20A (±4A) | 20A/30A (±4A) |
Charging algorithm | 4-step (Li) | ||
Solar charging model | |||
Max solar power input | 900W | 1800W | 1800W |
PV max charging current | 60A (±3A) | 60A (±3A) | 60A (±3A) |
Combined charging current | 70A (±4A) | 70A (±4A) | 80A (±4A) |
Max efficiency | 98.0% max | ||
PV array open circuit voltage | 75VDC | 100VDC | 100VDC |
PV Array MPPT Voltage Range | 15~75V | 30~80VDC | 30~80VDC |
Output | |||
USB (5V 2.4A) | DC output*2pcs | ||
USB (12V DC5.5, 3A) | DC output*1pc | ||
AC output | 4pcs | ||
Lishen LiFePO4 Battery | |||
Nominal energy | 1000Wh | 2000Wh | 3000Wh |
Life Cycles | 4000+ | ||
Nominal voltage | 12.8V | 25.6V | |
Normal charge voltage | 14.6V | 29.2V | |
Standard charging and discharge current | 50.0A | 50.0A | |
Maximum continuous charging and discharge current | 100.0A | 100.0A | |
End of discharge voltage | 10.0V | 20.0V | |
Operation temperature | |||
Charge | 0~45℃ | 0~45℃ | |
Discharge | -10~60℃ | -10~60℃ |