• Welcome to MUST ENERGY !

Power Inverters

Low Frequency Pure Sine Wave Inverter

EP3000 Pro Series (1-6KW)

EP3000 Pro series is very economical pure sine wave inverter , AC charger inbuilt , from 35A to 70A ; Solar /AC priority is configurable, When setting solar priority , solar will charge batteries as first priority , and AC can also charge batteries when solar charge current too lower , in this way system charge is optimazed best . With pure copper transformer , it enables inverter to operate with all kinds of home appliances .

Product Performance

  • LCD display
  • Pure Sine Wave Output
  • Support Remote Control Box(optional)
  • Compatible to generator
  • 5-levels DIP switch , offering customized performance
  • 9-levels battery selector , Enable to charge Li-thium , Gel , lead-acid battery
  • DC(Solar)/AC prority optional
  • 4 levels charge current adjustable
  • With RS232 communication port
  • With BTS & GTS , optimazing battery performance & start generator automatically
  • Power saver Switch , Enable to minimize standby consumption
MODELEP30-1KW PROEP30-1.5KW PROEP30-2KW PROEP30-3KW PROEP30-4KW PROEP30-5KW PROEP30-6KW PRO
Nominal Battery System Voltage12VDC24VDC12VDC24VDC12VDC24VDC12VDC24VDC48VDC24VDC48VDC24VDC48VDC24VDC48VDC
INVERTER OUTPUT
Rated Power1.0KW1.5KW2KW3KW4KW5KW6KW
Surge Rating(20ms)3.0KW4.5KW6.0KW9.0KW12KW15KVA18KW
Capable Of Starting Electric Motor1HP1HP1HP2HP3HP
WaveformPure sine wave / same as input (bypass mode)
Nominal Output Voltage RMS220V / 230V / 240V (±10% RMS)
Output Frequency50Hz / 60Hz ±0.3Hz
Inverter Efficiency (Peak)>88%
Line Mode Efficiency>95%
Power Factor1.0
Typical Transfer Time10ms(max)
AC INPUT
Voltage230VAC
Selectable Voltage Range96~132VAC 155~280VAC(For personal computers)
Frequency Range50Hz / 60Hz(Auto sensing) 40~80Hz
BATTERY
Minimum Start Voltage10.0VDC / 10.5VDC for 12VDC mode(*2 for 24VDC, *4 for 48VDC)
Low Battery Alarm10.5VDC ±0.3V for 12VDC mode(*2 for 24VDC, *4 for 48VDC)
Low Battery Cut Off10.0VDC ±0.3V for 12VDC mode(*2 for 24VDC, *4 for 48VDC)
High Voltage Alarm16.0VDC ±0.3V for 12VDC mode(*2 for 24VDC, *4 for 48VDC)
High Battery Voltage Recover15.5VDC ±0.3V for 12VDC mode
Idie Consumption-Search Mode<25W when power saver on
CHARGER
Output VoltageDepends on battery type
Charge AC Input Breaker Rating10A30A30A30A40A
Overcharge Protection S.D.15.7VDC for 12VDC mode (*2 for 24VDC mode, *4 for 48VDC mode)
Maximum Charge Current35A20A45A25A65A35A75A45A30A65A35A70A40A75A50A
BYPASS & PROTECTION
Input Voltage WaveformSine wave (grid or generator)
Nominal Input Frequency50Hz or 60Hz
Overload Protection (SMPS Load)Circuit breaker
Output Short Circuit ProtectionCircuit breaker
Bypass Breaker Rating10A30A30A30A30A40A
Max Bypass Current30Amp
MECHANICAL SPECIFICATIONS
MountingWall Mount
Dimensions (W*H*D)426*206*178mm601*206*178mm
Net Weight (Solar CHG)(kg)16.51721.1202624.524.838.235.845.24545.245
Shipping Dimensions (W*H*D)5570*335*300mm750*335*300mm
Shipping Weight (Solar CHG)(kg)19.32024.122.829.127.527.542.34049.549.349.549.3
OTHER
Operation Temperature Range0℃ to 40℃
Storage Temperature-15℃ to 60℃
Audible Noise60dB MAX
DisplayLED+LCD
Standard Warranty1 year