The EH9335 series of 3/3 UPS adopts double-change online design, with input power factor correction (PFC), which makes the input power factor as high as 0.99. It has a high energy density ratio, which greatly reduces its own volume and floor space of the computer room. Using digital control, the system is highly stable, with selfprotection and fault diagnosis capabilities. This series of UPS can better solve power supply problems such as instantaneous voltage drop, damping oscillation, high voltage pulse, surge voltage, harmonic distortion, clutter interference, and frequency fluctuation for users.
Model | EH9335- 10KS | EH9335- 20KS | EH9335- 30KS | EH9335- 40KS | EH9335- 60KS | EH9335- 80KS | EH9335- 10K | EH9335- 20K | EH9335- 30K | EH9335- 40K |
---|---|---|---|---|---|---|---|---|---|---|
Capacity | ||||||||||
Rated capacity | 10KAVA/9KW | 20KVA/18KW | 30KVA/27KW | 40KVA/32KW | 60KVA/54KW | 80KVA/64KW | 10KVA/9KW | 20KVA/18KW | 30KVA/27KW | 40KVA/32KW |
Input | ||||||||||
Input format | Three-phase four-line + ground | |||||||||
Rated input voltage | AC 380V/400V/415V | |||||||||
Voltage range | AC 208V~478V | |||||||||
Frequency range | 45-55Hz at50Hz / 54-66Hz at60Hz (Auto) | |||||||||
Input power factor | ≥0.99 | |||||||||
Input current harmonic | ≤3% (100% Nonlinear load) | |||||||||
Bypass range | Bypass protection voltage upper limit: 220V: +25% (Optional +10%, +15%, +25%)230V: +20% (Optional+ 10%, +15%)240V: +15% (Optional+10%) | |||||||||
Bypass protection voltage lower limit: -45% (Optional -20%-30%) | ||||||||||
Bypass frequency protection range: ±10% | ||||||||||
Outout | ||||||||||
Output format | Three-phase four-line + ground | |||||||||
Rated output voltage | AC 380V / 400V / 415V | |||||||||
Output power factor | 0.8 / 0.9 | |||||||||
Output accuracy | ±1% | |||||||||
Output frequency | Online mode: Follow the utility frequency; Battery Mode: 50/60Hz±0.2% | |||||||||
Output current harmonic | ≤ 2% Linear Load ≤ 5% Nonlinear Load | |||||||||
Battery | ||||||||||
Battery number | Optional: DC±192V/204V/216V/228V/240V (±16/17/18/19/20 pcs) default: DC±192V | 7Ah*20 | 7Ah*20 | 9Ah*20 | 9Ah*20 | |||||
Charging Current | 10A max | 20A max | 4A max | |||||||
Protection | ||||||||||
Overload protection | Load 110%, 60min; ≤ 125%, 10min; ≤ 150%, 1min; ≥ 150% Transfer to bypass immediately | |||||||||
Over Temperature Protection | Normal mode: switch to bypass mode; battery mode: shut down output immediately | |||||||||
Emergency shutdown (EPO) | Shut down output immediately | |||||||||
Maintenance bypass | Standard maintenance bypass switch | |||||||||
Other | ||||||||||
Switching time | Utility mode to bypass mode: 0ms; utility mode to battery mode: 0ms | |||||||||
Normal mode (full load) | ≥efficiency 94.5% | |||||||||
Communication interface | RS232,RS485,SNMP Card (optional), electric relay card (optional) | |||||||||
Energy Saving Mode (ECO) | Support | |||||||||
Self-check function | Support | |||||||||
Parallel function | Support up to 4 units in parallel | |||||||||
Executive standard | YD/T1095-2018 | |||||||||
Operating Environment | ||||||||||
Operating temperature | 0~40℃ | |||||||||
Storage temperature | -25~55℃ (batteries: 0~40℃ ) | |||||||||
Operating environment humidity | 0%~95% (no condensation) | |||||||||
Altitude | < 1500m, when above 1500m, when above 1500m, derate according to GB/T 3859.2 | |||||||||
Physical characteristi | ||||||||||
Size (D*W*H) (mm) | 690*250*734 | 775*335*978 | ||||||||
Net Weight (kg) | 50 | 50 | 51 | 52 | 89 | 90 | 164 | 1665 | 166 | 167 |